Testing Results
| Low Profile Sill | |
|---|---|
| Type of Test | |
* Air Infiltration: ASTM E-283, ft.3/min/ft. |
@ 1.56 psf (25 mph):0.19 |
* Water Penetration: |
Please note that due to varying site requirements and conditions, these sills will not be prepared for drainage by NanaWall Systems, Inc. If this drainage system is desired, we recommend that a qualified professional construt this system on the project site strictly in accordance with instructions provided by NanaWall Systems, Inc. and in accordance with good waterproofing techniques. If drain connections are not made or are not possible, unit may leak with wind driven rain.
|
Structural Load Deflection: ASTM E-330-90: pass See Design Windload Chart on page 14 for other sized panels. |
Unit with reinforced locking Design Pressure (positive and negative): |
Thermal Performance: |
Pending |
* Forced Entry Resistance |
In accordance with AAMA-1303.5 and CAWM 300-96 requirements. |
* Excerpts of results of a 10'5" W x 7'10" H three panel VSW unit (1 swing panel attached to a side jamb and 2 sliding panels. 1 sliding panel has offset detail 6.4 on 1 side) and reinforced locking tested by Architectural Testing, Inc., Fresno, CA, an independent testing laboratory in February 2003.

ENERGY STAR was created to help consumers easily identify products, homes, and buildings that save energy and money, and help protect the environment. As the government-backed, trusted symbol for energy efficiency, the ENERGY STAR label identifies highly efficient products and designates superior energy performance in homes and buildings.