Minimal Surface Mounted Flush Sill | Flush Sill – NW Acoustical 545
Type of Test | Inward Opening Units | Outward Opening Units |
---|---|---|
Air Infiltration 1ASTM E-283, ft3/min./ft. and NFRC 400 |
@ 1.57 psf (75 Pa): 0.11 A2 @ 6.24 psf (300 Pa): 0.25 |
@ 1.57 psf (75 Pa): 0.13 A2 @ 6.24 psf (300 Pa): 0.28 |
Forced Entry Resistance 1AAMA-1304 |
In accordance with AAMA -1304 requirements 1 (European PAS24 Certified with optional security package) |
|
Operating Force 1ASTM E2068 |
The NW Acoustical 545 meets:
|
|
Operation / Cycling PerformanceAAMA 920 & DIN EN 1191 Windows and Pedestrian Doors - Mechanical Durability |
The NW Acoustical 545 meets:
|
1 Derived from excerpts of results of 13′1″ W x 8′6″ H (4000 mm x 2600 mm) 4 panel unit (1L3R configuration) with low profile saddle sill specific or equivalent to lab tested by Intertek Building & Construction, an independent testing laboratory in March 2020 per AAMA/WDMA/CSA 101/I.S.2/A440-17, NAFS-17 - North American Fenestration Standard